Command Palette

Search for a command to run...

UnylyUnyly
Весь каталог

Rs3005p

БесплатноНе проверен

An MCP server that lets AI agents control an RS PRO RS-3005P/RS-6005P programmable DC power supply over USB/RS232, enabling voltage/current control, measurement

GitHubEmbed

Описание

An MCP server that lets AI agents control an RS PRO RS-3005P/RS-6005P programmable DC power supply over USB/RS232, enabling voltage/current control, measurements, output switching, and memory operations.

README

An MCP server that lets AI agents control an RS PRO RS-3005P (or RS-6005P) digital programmable DC power supply over its USB / RS232 serial interface.

It implements the documented RS Series Remote Control Syntax V2.0 (KORAD-compatible) and exposes voltage/current control, live measurements, output and over-current-protection switching, and panel-memory save/recall as MCP tools.

Supported hardware

Model Voltage Current Remote interface
RS-3005P 0–30 V 0–5 A USB + RS232
RS-6005P 0–60 V 0–5 A USB + RS232

The non-P variants (RS-3005D / RS-6005D) have no remote interface and cannot be driven by this server.

Serial settings (fixed by the firmware): 9600 baud, 8 data bits, no parity, 1 stop bit, no flow control.

Install

uv venv
uv pip install -e .

Run

The server speaks MCP over stdio:

uv run rs3005p-mcp

Claude Code / Claude Desktop config

{
  "mcpServers": {
    "rs3005p": {
      "command": "uv",
      "args": ["run", "rs3005p-mcp"],
      "cwd": "C:/path/to/rs3005p-mcp"
    }
  }
}

Tools

Tool Purpose
list_serial_ports Discover the COM/tty port the supply is on.
connect Open the port, pick the model, verify with *IDN?.
disconnect Close the connection.
get_identification Read the *IDN? string.
get_safety_profile Read the active safety envelope (read-only).
list_devices List device profiles in the library + which is active.
select_device Switch active profile (widening needs confirm_widen).
set_voltage Set the voltage setpoint (range + safety validated).
set_current Set the current limit (range + safety validated).
ramp_voltage Ramp voltage to a target within the slew limit.
power_up Bring the DUT to its profile's nominal operating point.
get_setpoints Read configured voltage & current setpoints.
measure Read actual output voltage & current.
set_output Enable/disable the output terminals.
set_ocp Arm/disarm over-current protection.
get_status Decoded status: output, CV/CC mode, OCP.
get_state Full snapshot (setpoints + measurements + status).
save_settings Store panel settings to memory slot 1–5.
recall_settings Recall panel settings from memory slot 1–5.

Safety profiles (protecting attached devices)

To stop an agent from over-driving the device wired to the terminals, supply a device-profile library at launch. It defines a safe envelope (voltage / current / power ceilings, output gating, slew limit) per device; the server rejects any agent request that would leave it. Profiles are set by the operator at startup and cannot be changed by any tool.

rs3005p-mcp --profile devices.json --device 24v-sensor

RS3005P_DEVICE/--device is only the default; an agent can switch among the curated devices at runtime with select_device (widening the envelope requires confirm_widen=true) and devices.json edits hot-reload on the next connect/select_device — no re-registration. No tool can create or modify a profile's limits; the file stays operator-curated.

See docs/safety.md and examples/devices.example.json. With no profile the server runs limited only by hardware (30 V / 5 A) and says so on every connect.

A typical agent flow:

  1. list_serial_ports → find the port.
  2. connect(port="COM4") → verifies identity, applies RS-3005P limits.
  3. set_voltage(5.0), set_current(0.5).
  4. set_output(True).
  5. measure() → live readings.

Development

uv pip install -e ".[dev]"
uv run pytest

Tests run against an in-memory device emulator (tests/conftest.py), so no hardware is required. See docs/ for the protocol reference and architecture notes.

License

MIT.

from github.com/Gigaclank/RS3005P-MCP

Установить Rs3005p в Claude Desktop, Claude Code, Cursor

Рекомендуется · одна команда, все IDE
unyly install rs3005p-mcp

Ставит в Claude Desktop, Claude Code, Cursor и VS Code — сам разбирается с npx, uvx и сборкой из исходников.

Впервые? Поставь CLI: curl -fsSL https://unyly.org/install | sh

Или настроить вручную

Выполни в терминале:

claude mcp add rs3005p-mcp -- uvx --from git+https://github.com/Gigaclank/RS3005P-MCP rs3005p-mcp

FAQ

Rs3005p MCP бесплатный?

Да, Rs3005p MCP бесплатный — установка в пару кликов через Unyly без оплаты.

Нужен ли API-ключ для Rs3005p?

Нет, Rs3005p работает без API-ключей и переменных окружения.

Rs3005p — hosted или self-hosted?

Self-hosted: сервер запускается локально на твоей машине командой из раздела установки.

Как установить Rs3005p в Claude Desktop, Claude Code или Cursor?

Открой Rs3005p на unyly.org, выбери вкладку своего клиента (Claude Desktop, Claude Code, Cursor) и нажми Install — конфиг сгенерируется автоматически, без правки JSON.

Похожие MCP

Compare Rs3005p with

Не уверен что выбрать?

Найди свой стек за 60 секунд

Автор?

Embed-бейдж для README