An MCP server for controlling Rigol DS1000Z series oscilloscopes over LAN using natural language. It enables users to take measurements, configure instrument se
An MCP server for controlling Rigol DS1000Z series oscilloscopes over LAN using natural language. It enables users to take measurements, configure instrument settings, and capture screenshots directly through an MCP client.
MCP server for controlling Rigol DS1000Z and DHO series oscilloscopes over LAN or USB. Exposes the scope as a set of tools that Claude (or any MCP client) can call to take measurements, configure the instrument, and capture screenshots — entirely through natural language.

Unknown signal (square wave into LCR trap), wrong channel enabled, invalid timebase/voltage/trigger. Claude identifies the signal type, corrects the setup, and characterises the waveform.

Rigol DS1000Z / MSO1000Z series (8-bit):
| Model | Channels | Notes |
|---|---|---|
| DS1054Z | 4 analog | Most common, 50 MHz |
| DS1074Z | 4 analog | 70 MHz |
| DS1074Z-S | 4 analog + signal gen | |
| DS1104Z | 4 analog | 100 MHz |
| DS1104Z-S | 4 analog + signal gen | |
| MSO1054Z | 4 analog + 16 digital | MSO variant |
| MSO1074Z | 4 analog + 16 digital | |
| MSO1104Z | 4 analog + 16 digital |
Rigol DHO series (12-bit):
| Model | Channels | Notes |
|---|---|---|
| DHO924S | 4 analog + signal gen | 250 MHz |
Other DHO models (DHO900/1000/4000 families) likely work with the same SCPI dialect but are not verified.
The scope connects either over your local network via Ethernet (rear panel RJ45) or over USB (rear panel USB-B device port). LAN is the default; USB is used when RIGOL_USB is set (see Configuration). USB transport has been validated on DS1000Z; DHO support has so far been validated over LAN only.
git clone https://github.com/erebusnz/rigol-mcp
cd rigol-mcp
uv sync
On the scope, go to Utility → IO Setting → LAN and note the IP address (or assign a static one). The scope listens on port 5555 for raw SCPI commands — no additional configuration is needed.
Replace 192.168.1.123 with the IP address of your scope in all instructions below.
Verify in browser: http://192.168.1.123/DS1000Z_WelcomePage.html
Verify connectivity before using as MCP:
python -c "import pyvisa; rm = pyvisa.ResourceManager('@py'); s = rm.open_resource('TCPIP0::192.168.1.123::5555::SOCKET'); s.write_termination='\n'; s.read_termination='\n'; print(s.query('*IDN?'))"
You should see something like:
RIGOL TECHNOLOGIES,DS1054Z,DS1ZA123456789,00.04.04.SP4
Set the scope IP for MCP via environment variable:
export RIGOL_IP=192.168.1.123
Or create a .env file (copy from .env.example):
RIGOL_IP=192.168.1.123
Optional:
| Variable | Default | Description |
|---|---|---|
RIGOL_IP |
(required for LAN) | Scope IP address |
RIGOL_USB |
(unset) | Set to 1 to connect over USB instead of LAN. The first Rigol USB scope is found automatically. |
RIGOL_USB_SERIAL |
(unset) | When several Rigol scopes are on USB, pin a specific one by serial number. |
RIGOL_ENABLE_SEND_RAW |
(unset) | Set to 1 to enable the send_raw tool (arbitrary SCPI). Off by default — see Tools. |
RIGOL_SCREENSHOT_DIR |
screenshots/ |
Directory for saved PNG screenshots |
Set RIGOL_USB=1 to connect over USB instead of LAN. The server looks for a Rigol scope
on USB (vendor ID 0x1AB1) and connects to it. If more than one scope is connected, set
RIGOL_USB_SERIAL to choose which one by serial number.
RIGOL_USB=1
# RIGOL_USB_SERIAL=DS1ZA000000000 # only needed if more than one scope is on USB
The scope's USB interface needs a VISA-compatible driver. The server auto-detects whichever you have installed — pick one:
Option A — install the WinUSB driver with Zadig. The server talks to the scope through
the bundled pure-Python pyvisa-py (@py) backend (pyusb + libusb); no extra Rigol
software needed. Do this once per scope:
RIGOL_USB=1.Option B — install Rigol UltraSigma, which bundles the driver.
UltraSigma installs the standard "USB Test and Measurement
Device" (USBTMC) driver. Once it's installed, the server reaches the scope through the
NI-VISA (@ivi) backend — nothing else to configure.
Note: the two drivers are mutually exclusive on a given USB interface. Installing WinUSB (Option A) means UltraSigma can no longer see the scope over USB until you revert the driver in Device Manager, and vice versa. LAN access is unaffected either way.
Works without needing drivers using the pyvisa-py (@py) backend.
macOS: typically works as-is once RIGOL_USB=1 is set; no driver to install.
Linux: give your user permission to claim the device with a udev rule, then replug it:
# /etc/udev/rules.d/60-rigol.rules
SUBSYSTEM=="usb", ATTRS{idVendor}=="1ab1", MODE="0660", GROUP="plugdev"
sudo udevadm control --reload-rules && sudo udevadm trigger
(Make sure your user is in the plugdev group: sudo usermod -aG plugdev $USER, then log out and back in.)
If the kernel's usbtmc module has already claimed the scope, unbind or blacklist it so
libusb can take the interface — pyvisa-py does not detach it automatically.
USB is currently hardware-tested on Windows only; Linux/macOS use the standard
libusbsetup above.
Add to your .mcp.json (or Claude Desktop MCP config):
{
"mcpServers": {
"rigol": {
"command": "uv",
"args": ["run", "rigol-mcp"],
"cwd": "/path/to/rigol-mcp",
"env": {
"RIGOL_IP": "192.168.1.123"
}
}
}
}
For USB, replace the RIGOL_IP entry in env with "RIGOL_USB": "1" (see USB connection).
| Tool | Description |
|---|---|
idn |
Identify the instrument — make, model, serial, firmware |
get_scope_state |
Snapshot of all channel configs, timebase, and trigger settings |
| Tool | Description |
|---|---|
run |
Start continuous acquisition |
stop |
Stop and freeze display |
single |
Arm for one trigger event, then stop |
autoscale |
Auto-configure timebase, vertical scale, and trigger |
| Tool | Description |
|---|---|
set_channel |
Set scale (V/div), offset, coupling (AC/DC/GND), probe ratio, on/off |
set_timebase |
Set time/div and trigger offset |
set_trigger |
Configure edge trigger: source, slope (POS/NEG/RFAL), level |
| Tool | Description |
|---|---|
measure |
Query any single-channel measurement: VMAX, VMIN, VPP, VTOP, VBASE, VAMP, VAVG, VRMS, PVRMS, VUPPER, VMID, VLOWER, VARIANCE, FREQUENCY, PERIOD, PWIDTH, NWIDTH, PDUTY, NDUTY, RTIME, FTIME, OVERSHOOT, PRESHOOT, PSLEWRATE, NSLEWRATE, TVMAX, TVMIN, MAREA, MPAREA, PPULSES, NPULSES, PEDGES, NEDGES |
measure_between |
Query delay or phase between two channels. DS1000Z: RDELAY, FDELAY, RPHASE, FPHASE. DHO: RRDELAY/RFDELAY/FRDELAY/FFDELAY, RRPHASE/RFPHASE/FRPHASE/FFPHASE (DS1000Z names auto-map to the homogeneous-edge DHO equivalents) |
get_waveform |
Download and analyse waveform data (NORM screen buffer: up to 1200 pts on DS1000Z, 1000 on DHO); returns text analysis by default, raw time/voltage arrays with raw_data=true |
| Tool | Description |
|---|---|
set_cursors |
Set cursor mode (MANUAL/TRACK/OFF) and time positions in seconds |
get_cursor_values |
Read cursor positions (in seconds) and all delta/amplitude readouts |
| Tool | Description |
|---|---|
screenshot |
Capture display as PNG — returns image inline and saves to disk |
send_raw |
Send any SCPI command directly (escape hatch). Disabled by default — set RIGOL_ENABLE_SEND_RAW=1 to expose it, since arbitrary SCPI can leave the scope in any state. |
check_error |
Query the SCPI error queue |
Basic measurement session:
"Connect to the scope, check what's configured, then measure the frequency and Vpp on channel 1."
Signal characterisation:
"Stop the scope, download the waveform from channel 2, and tell me the rise time, overshoot percentage, and estimated fundamental frequency."
Setup from scratch:
"Set channel 1 to 2V/div DC coupling with a 10x probe, set the timebase to 1ms/div, trigger on channel 1 rising edge at 1V, then run and take a screenshot."
Cursor measurement:
"Put manual cursors on the first rising edge of the signal on channel 1 — cursor A at the 10% level and cursor B at the 90% level — and read the rise time from the delta."
Transient / ringing characterisation:
"There's a damped oscillation on channel 1 after a step edge. Stop the scope, measure Vpp, Vmax, Vmin, and Vrms, then estimate the ring frequency and how many cycles it takes to decay."
Iterative debugging:
"I'm verifying the gain of an amplifier. Channel 1 is the input, channel 2 is the output. The expected gain is 20 dB. Figure out whether it's within spec."
Unknown signal characterisation:
"There's an unfamiliar signal on channel 1. I don't know its frequency, amplitude, or shape. Keep adjusting the timebase and vertical scale until you have a stable, well-framed view of at least two full cycles, then give me a complete characterisation of what you see."
Claude / MCP client
│ MCP protocol (stdio)
rigol_mcp.server ← tool definitions, request routing
│ Python function calls
rigol_mcp.scope ← VISA connection, SCPI command helpers
│ SCPI over TCP/IP (port 5555) or USBTMC
Rigol DS1000Z ← 192.168.1.123 / USB
The VISA connection is cached across tool calls (one connection per server session) and reconnects automatically on communication errors.
By default the server connects using raw socket VISA (TCPIP0::<ip>::5555::SOCKET), not VXI-11. This avoids the NI-VISA dependency and works with the pure-Python pyvisa-py backend. It also eliminates the VXI-11 handshake overhead, making individual commands faster.
When RIGOL_USB is set, the server instead connects over USBTMC (USB0::0x1AB1::<model>::<serial>::INSTR), discovering the scope automatically. It auto-selects whichever VISA backend can see the scope:
@py (pyvisa-py + pyusb + bundled libusb) — for a USB interface bound to WinUSB (no NI-VISA needed).@ivi (NI-VISA / IVI VISA) — for the native USBTMC driver (e.g. installed with Rigol UltraSigma).The two backends frame USBTMC reads differently, so block reads (waveform/screenshot) are read by exact byte count on @py and via native message reads (read_raw) on @ivi. Transport and backend selection live in rigol_mcp.scope.get_scope / _open_usb_scope.
Unit tests are fully offline — the VISA layer is faked, so no instrument is required.
uv run --extra test pytest # or: uv sync --extra test && uv run pytest
libusb access (a udev rule) or NI-VISA; macOS typically works through libusb with no setup. The server auto-detects the backend — see USB connection. LAN needs no driver setup on any platform.send_raw for thoseMIT — see LICENSE.